Reconstitution & Dosing

Professional use only

Peptide Dosage Calculator

Enter what’s on your vial, how much bacteriostatic water you’re adding, and the prescribed dose. We’ll show you exactly where to draw your syringe — plus a step-by-step guide to mixing the vial correctly.

The total milligrams printed on the vial label.

mg

Tap a common size, or choose Other to enter your own.

What is this & how do I fill it in?

This is the total amount of freeze-dried (lyophilized) peptide powder in the vial — not the amount per dose. Look for it on the label, e.g. “10 mg”.

  • Most vials are labeled in milligrams (mg).
  • If yours is labeled in micrograms (mcg), divide by 1,000 to get mg. Example: 5,000 mcg = 5 mg.
  • Larger vials work too — just type the number into the field.

The liquid you’ll mix into the vial. This sets the concentration.

mL

Common amounts: GLP-1s 2–3 mL · most other peptides 3 mL. Choose Other to enter your own.

What is this & how do I fill it in?

Bacteriostatic water is sterile water with 0.9% benzyl alcohol, which inhibits bacterial growth so the vial can be drawn from more than once.

The water doesn’t change how much peptide you have — only how concentrated it is. It’s like juice from concentrate: same amount of juice, more or less water.

  • More water → weaker solution → more units per dose. Good for small doses you want to measure precisely.
  • Less water → stronger solution → fewer units per dose. Good when a large dose won’t fit in the syringe.
  • If the product documentation specifies a reconstitution volume, use that.
  • Make sure the vial has room for the amount of water you add.

The prescribed amount for a single dose.

mg

 

What is this & how do I fill it in?

Enter the amount of peptide for one dose, exactly as written in the protocol or prescription.

  • Check the unit. 1 mg = 1,000 mcg. Mixing these up is the most common error — 250 mcg is 0.25 mg, not 250 mg.
  • Use the mcg / mg switch to match how your dose is written. Switching converts the number for you.
  • “mcg” and “µg” mean the same thing (micrograms).

This calculator doesn’t recommend doses — it only converts the dose you enter into a syringe measurement.

Syringe size

The U-100 insulin syringe you’ll measure with. Default: 31-gauge, 100-unit.

What is this & how do I fill it in?

Insulin syringes are marked in units instead of mL. On a U-100 syringe, 100 units = 1 mL, so 1 unit = 0.01 mL.

  • Sizes: 30 units = 0.3 mL · 50 units = 0.5 mL · 100 units = 1 mL. The calculator warns you if a dose won’t fit.
  • Lines: 100-unit syringes typically have a line every 2 units (numbered every 10); 30- and 50-unit syringes typically have a line every 1 unit (numbered every 5).
  • Smaller syringes space their lines further apart, so they’re easier to read for small doses. The 100-unit syringe is the most common and fits the widest range of doses.
  • 31-gauge (31G) is the needle’s thickness — the higher the number, the thinner the needle. A 31G needle is very fine, so liquid moves through it slowly and the needle can bend if forced.
  • Only use U-100 syringes with this calculator — U-40 syringes are scaled differently.

Step-by-step guide

How to fill your 31G, 100-unit syringe

These steps update with your numbers above — highlighted values come straight from the calculator. Already mixed your vial? Skip to step 05.

  1. 01

    Gather your supplies

    Your 5 mg peptide vial, bacteriostatic water, alcohol prep pads, new 31G, 100-unit insulin syringes, and a sharps container.

  2. 02

    Prep a clean workspace

    Wash your hands. Flip the plastic caps off both vials and wipe each rubber stopper with a fresh alcohol pad. Let them air-dry — don’t blow on them.

  3. 03

    Mix the vial (first use only)

    Draw 2 mL of bacteriostatic water. Insert the needle into the peptide vial and let the water run slowly down the glass wall, not directly onto the powder.

  4. 04

    Dissolve & label

    Swirl gently or roll the vial between your palms — don’t shake. It should turn clear; don’t use it if it’s cloudy or has particles. Label it 2.5 mg/mL with today’s date, and store it as directed in the product documentation.

  5. 05

    Load the syringe with air

    Take a new syringe and wipe the vial stopper again. Pull the plunger back to 10 units so the syringe holds the same amount of air as the dose you’ll draw.

  6. 06

    Insert straight & add the air

    Push the needle straight down through the center of the stopper — a 31G needle is very fine and can bend if angled. Press the air into the vial. This keeps the pressure even so the liquid draws smoothly.

  7. 07

    Turn it over & draw slowly

    Flip the vial upside down with the syringe still in it. Keep the needle tip below the liquid line. Pull the plunger slowly — the thin 31G needle lets liquid in gradually, and pulling fast makes bubbles. Go a few units past 10 units.

  8. 08

    Clear bubbles & set the dose

    Still upside down, flick the barrel so bubbles rise to the needle and push them back into the vial. Then press the plunger until the front edge of the rubber stopper sits exactly on 10 units.

  9. 09

    Double-check & remove

    At eye level, confirm the reading: 10 units = 250 mcg. Pull the syringe straight out of the vial. Use each syringe once — fine needles dull quickly — then discard it in a sharps container.

Reading your syringe

Where exactly is the line?

Read here ← needle side
  • Read the measurement at the front edge of the rubber stopper — the flat edge closest to the needle, not the back of the stopper.
  • On your 31G, 100-unit syringe, each small line is typically 2 units, with numbers every 10 units. Odd numbers (like 15) sit halfway between two lines.
  • 10 units = 0.1 mL. Units always mean hundredths of a mL on a U-100 syringe.
  • Hold the syringe at eye level so the lines aren’t distorted, and make sure there are no air bubbles before you read it.

The math

How we got your number

  1. Concentration vial amount ÷ water 5 mg ÷ 2 mL = 2.5 mg/mL
  2. Dose volume dose ÷ concentration 0.25 mg ÷ 2.5 mg/mL = 0.1 mL
  3. Syringe units volume × 100 0.1 mL × 100 = 10 units
  4. Doses per vial vial amount ÷ dose 5 mg ÷ 0.25 mg = 20

Quick check: double the water and you double the units you draw — but the amount of peptide in each dose stays the same.

For licensed healthcare professionals. This calculator performs arithmetic only; it does not recommend doses or replace clinical judgment. Always verify results against the prescription and product documentation before use.